Outdoor Switches TFortis PSW and TFortis SWU
0.2.8 (since 01.06.2021)
What's new?
- PSW-2G+Box,PSW-2G6F+Box, PSW-2G8F+Box support is added
- fixed: hanging when receiving large frames
- SNMP: State and Alarm State for dry contacts are modified according to documentation
- SNMP: ifXTable implementation is added
- Output setting and status via SNMP are added in UPS+ switches
- Setting of temperature thresholds via SNMP is added
- Operation with NetXMS monitoring system is fixed: incorrect speed calculation
- SNMP Object ID is fixed to 1.3.6.1.4.1.42019
- Displaying the battery voltage graph is added for switches with UPS
- UPS: calculation of the consumed power when operating on battery power, voltage and time forecast recording to logs
- Display of "PoE A" in PoE statistics changed to "PoE"
- The ability to control the relay output by inputs transfer from Teleport units is added in UPS+ series switches
- A button to clear the MAC address table is added
- The length of recordings in the logs is increased to 80 characters
- Port number mapping in ARP table is added
- The problem with duplicate entries in the MAC table is fixed
- Temperature / humidity sensor SHT-01 support is added
- Leakage sensor support is added
- Limit values for temperature, humidity, sending messages are added
- For UPS+: inputs / outputs tab, gray out the initial state if the output mode is transfer
- Output control and temperature sensor is added to http-api
- "Passive A" port operation mode is added in PoE+ switches
- Problem fixed: LLDP packets pass through the switch when LLDP is enabled
- Problem fixed: LLDPs do not arrive on SWU-16, devices are not seen
- SNTP: if time synchronization fails time is not displayed (in logs)
- Problem fixed: not all devices are detected correctly in TFortis Device Manager
- MAC address aging mechanism fixed in SWU-16 switches
- Debug mode is added for RSTP
- The size of web interface sources is optimized
- Logging setting is added
- Watchdog function is added: ping a third-party server and reboot the switch if there are no 100 responses in a row
- Port mirroring function in PSW switches is added
- Read Only user type for web interface and telnet is added
- The ability to upload a configuration file only with changes is added
- Operation with dry contact inputs on PSW-2G2F+UPS is fixed
- The problem with the inaccessibility of the web interface after the update is fixed
- Cooperation with the PVST+ protocol is fixed
0.2.7 (since 10.04.2020)
What's new?
- issue with launching VCT on PSW-2G8F for ports 7.8 was fixed
- baud rate via RS-485 for UPS + series units was changed
- SNMP full ifXTable implementation wasadded
- SNMP: problem with SNMPWalk command was fixed
- SNTP: wrong date and time issue was fixed
- in the UPS + series switches, the relay output is controlled through the unit Teleport
- integration display of port status in off state was fixed
- the problem with saving port descriptions in Russian was fixed
0.2.4 (0.2.1 since 11.06.2019)
What's new?
- LLDP protocol was added
- Text description of ports was added
- The problem with port settings in PSW-1G4F was fixed
- Telnet:
- timeout for connection time was added
- configuration problems were fixed
- a problem with authorization was fixed
- A maximum speed control option was added to the anti-hang function
- A scheduled reboot was added to the anti-hang function
- TFortis Device Manager:
- applying the parameters is performed without rebooting
- reboot and reset commands were added
- New SNMP variables were added
- The problem with disabling Forwarding BPDU through a web interface was fixed
- There are changes in the protocol of interaction between Teleport units: data size is 128 bytes.
- The ability to create static ARP records was added
- IP address from which access to the switch was made is displayed in the logs
- SFP DDM: optical power is displayed in dBm
- Port Uptime parameter was added
- SNMP: the problem with reading variables from random Community was fixed
- A bug with sending SMTP messages was fixed, a display of sending errors was added
- TFortis UPS+ unit support for PSW-2G+, PSW-2G6F+, PSW-2G8F+ switches was added
- A problem with restoring configuration from file was fixed
0.2.3 (0.2.1 since 09.07.2018)
What's new?
- Operation with ActiveCam cameras is improved
- Additional port statistics is added
- Search by the port number in MAC address table is added
- Port Base VLAN setting is fixed
- Interaction protocol with Teleport devices is changed (Software update in Teleport up to version 1.2 is required)
- http API support for integrating switches into third-party software is added
- The ability to view IP and MAC addresses of devices connected to ports through TFortis Scanner (version 2.1.0 and up)